Bitumen 85/100 is also one the most popular bitumen grades for industrial usages, road construction and other projects.
The bitumen is provided during the process of oxidation of vacuum bottom in bitumen production units, Due to its relatively low air blowing and penetration, is used in cold areas. Below is the product's specification table which will be documented and certified by SGS or any third party inspection company the client wishes
Analysis | Unit | Limit | Test Method |
Density @ 25 °C | Kg/m³ | 1000 - 1050 | D70 or D3289 |
Penetration @ 25 °C | mm/10 | 85/100 | D5 |
Softening point °C | °C | 45/52 | D36 |
Ductility @ 25 °C | cm | 100 min | D113 |
Loss on Heating | wt% | 0.5 max | D6 |
Drop in Penetration after Heating | % | 20 max | D5 |
Flash point | °C | 232 min | D92 |
Solubility in Trichloroethylene | wt% | 99.0 min | D2042 |
Spot test | - | Negative | A.A.S.H.O.T 102 |
Viscosity @60 °C | P | 1000 +- 200 | D2171 |
Viscosity @135 °C | cSt | 250 min | D2170 |
Test on residue From thin film Oven Test (ASTM D1754) | |||
Retained Peneteration after TFOT | % | 50 min | D5 |
Ductility 25 °C 5 cm/min, afer TFOT | cm | 75 | D113 |
Viscosity @60 °C | P | 5000 max | D2171 |